Message: Return type of CI_Session_files_driver::open($save_path, $name) should either be compatible with SessionHandlerInterface::open(string $path, string $name): bool, or the #[\ReturnTypeWillChange] attribute should be used to temporarily suppress the notice
Message: Return type of CI_Session_files_driver::close() should either be compatible with SessionHandlerInterface::close(): bool, or the #[\ReturnTypeWillChange] attribute should be used to temporarily suppress the notice
Message: Return type of CI_Session_files_driver::read($session_id) should either be compatible with SessionHandlerInterface::read(string $id): string|false, or the #[\ReturnTypeWillChange] attribute should be used to temporarily suppress the notice
Message: Return type of CI_Session_files_driver::write($session_id, $session_data) should either be compatible with SessionHandlerInterface::write(string $id, string $data): bool, or the #[\ReturnTypeWillChange] attribute should be used to temporarily suppress the notice
Message: Return type of CI_Session_files_driver::destroy($session_id) should either be compatible with SessionHandlerInterface::destroy(string $id): bool, or the #[\ReturnTypeWillChange] attribute should be used to temporarily suppress the notice
Message: Return type of CI_Session_files_driver::gc($maxlifetime) should either be compatible with SessionHandlerInterface::gc(int $max_lifetime): int|false, or the #[\ReturnTypeWillChange] attribute should be used to temporarily suppress the notice
Veterinary X-ray Machine KVX-A100 is a portable, ultra-compact high frequency digital radiography system specifically designed for equine, bovine, exotic and multi-species x-ray imaging practices. X-ray assembly features accurate simulation-control, precise tube-voltage and tube-current with various pre-defined anatomical x-ray positioning con suitable for easy orientation and imaging.
Specifications :
Max Output Power
4 kW
Nominal Power
100 kV, 40mA, 0.1 s, 4 kW
Input Power
220 V ± 2 V (AC); 50/60 Hz
Tube Focus-spot
0.6 / 1.5 mm
Digital Detectors
Limit Resolution : 3.6 LP/mm Pixel Area : 427 × 356 mm A/D conversion : 14 bit
Power Capacity
≥ 5 kVA
Frequency
≥ 40 kHz
Tube voltage (kV Range)
40 kV ─ 110 kV
Tube current (mA Range)
36 mA ─ 70 mA
Radiographic density (mAs Range)
1 mAs ─ 200 mAs
Time Range
0.04 s ─ 3.2 s
Inner Resistance
≤ 0.50
Anode Heat Capacity
76 kHU
X-Ray Pre-set Positioning
48 anatomical positions
Dimensions
290 × 260 × 230 mm
Weight
18.8 Kgs
Features :
Digital double loop technology
Auto-test and failure self-protection facility
Digital LED display for tube-voltage and tube-current settings
Concise X-ray focusing
Consistent Image quality
Applications :
Used in outdoor or indoor radiography practices for diagnostic X-ray imaging in the pet clinic, rescue diagnosis, horse-stable or barn or cattle-shed for on-the-go X-ray imaging practices.