Message: Return type of CI_Session_files_driver::open($save_path, $name) should either be compatible with SessionHandlerInterface::open(string $path, string $name): bool, or the #[\ReturnTypeWillChange] attribute should be used to temporarily suppress the notice
Message: Return type of CI_Session_files_driver::close() should either be compatible with SessionHandlerInterface::close(): bool, or the #[\ReturnTypeWillChange] attribute should be used to temporarily suppress the notice
Message: Return type of CI_Session_files_driver::read($session_id) should either be compatible with SessionHandlerInterface::read(string $id): string|false, or the #[\ReturnTypeWillChange] attribute should be used to temporarily suppress the notice
Message: Return type of CI_Session_files_driver::write($session_id, $session_data) should either be compatible with SessionHandlerInterface::write(string $id, string $data): bool, or the #[\ReturnTypeWillChange] attribute should be used to temporarily suppress the notice
Message: Return type of CI_Session_files_driver::destroy($session_id) should either be compatible with SessionHandlerInterface::destroy(string $id): bool, or the #[\ReturnTypeWillChange] attribute should be used to temporarily suppress the notice
Message: Return type of CI_Session_files_driver::gc($maxlifetime) should either be compatible with SessionHandlerInterface::gc(int $max_lifetime): int|false, or the #[\ReturnTypeWillChange] attribute should be used to temporarily suppress the notice
Urine analyzer KUA-A100 is a high-precision handheld strip-based urine test equipment. Microprocessor based reader, monitors test and ensures repeatability. Docking system provides a print-out of the quantitative measurements. Built-in program controls development time for test strip before analysis. One touch data transfer and review streamlines data management.
Specifications :
Method
RGB Tricolor test
Test mode
Single-step test
Strip compliance
8, 10, 11, 12, 14 parameter test strips
Memory
Stores up to 500 records
Repeatability
CV ≤ 1%
Stability
CV ≤ 1%
Display
2.4-inch LCD (320 x 240 resolution)
Interface
Micro USB interface
Record mode
Flash ROM data storage
Power
100 V – 240 V, 50 / 60 Hz
Power consumption
≤ 5 W
Battery
Rechargeable Li-ion battery, 3.7 V, 1900 mAh
Dimensions
126 x 74 x 30 mm
Weight
200 g
Features :
Automated and large data storage
Micro USB interface
Bluetooth connectivity (optional)
Compliant with all urinalysis strips
Applications :
Used in small to medium sized nephrology clinics, medical camps, for long-term monitoring of nephrotic diseases, clinical inspection of urine to screen for potential conditions or diseases affecting the kidney or urinary tract.