Message: Return type of CI_Session_files_driver::open($save_path, $name) should either be compatible with SessionHandlerInterface::open(string $path, string $name): bool, or the #[\ReturnTypeWillChange] attribute should be used to temporarily suppress the notice
Message: Return type of CI_Session_files_driver::close() should either be compatible with SessionHandlerInterface::close(): bool, or the #[\ReturnTypeWillChange] attribute should be used to temporarily suppress the notice
Message: Return type of CI_Session_files_driver::read($session_id) should either be compatible with SessionHandlerInterface::read(string $id): string|false, or the #[\ReturnTypeWillChange] attribute should be used to temporarily suppress the notice
Message: Return type of CI_Session_files_driver::write($session_id, $session_data) should either be compatible with SessionHandlerInterface::write(string $id, string $data): bool, or the #[\ReturnTypeWillChange] attribute should be used to temporarily suppress the notice
Message: Return type of CI_Session_files_driver::destroy($session_id) should either be compatible with SessionHandlerInterface::destroy(string $id): bool, or the #[\ReturnTypeWillChange] attribute should be used to temporarily suppress the notice
Message: Return type of CI_Session_files_driver::gc($maxlifetime) should either be compatible with SessionHandlerInterface::gc(int $max_lifetime): int|false, or the #[\ReturnTypeWillChange] attribute should be used to temporarily suppress the notice
Stationary X-Ray Machine KSX-A100 series is a traditional X-ray imaging modality equipped with single focus X-ray source and full wave rectification high-voltage generator for reliable performance. The high voltage X-ray generator has an independent configuration for electrical isolation subsequently increasing safety and stability. X-ray tube incorporates space charge compensator and pressure regulator to ensure the sharp images and low X-ray dosage on every output.
Specifications :
Exposure Voltage
50 kV ~ 90 kV
Exposure Current
Small focus: 25 mA Big focus: (50, 75, 100 and 125) mA
Max. Output Voltage
90 kV
Max. Output Current
100 mA
Exposure Time
0.04 s ~ 6.3 s, 23 grades
Supply Voltage
Single Phase ; 380 V/220 V
Supply Frequency
50 Hz
Power Capacity
10 kVA
Inner Resistance
380 V: 2° 220 V: 0.6°
Glide Up/Down
720 mm – 1800 mm
HV Generator
7 kVA
X-Ray Focus
Big: 4.3 mm Small: 1.8 mm
Bed Dimensions
1960 × 660 × 700 mm
Cassette Size
356 × 432 mm or (14" ×17")
Features :
Standard Frequency X-Ray Generator
7 kVA Generator Capacity
Vibrating Ray-Filter Radiographic Flatbed
High Quality Imaging
Accurate Timer Controlled Exposure
Suitable for Radiography as well as Fluoroscopy
Step Less Adjustability of Controls
Applications :
Used in hospital radiology departments, orthopedic and diagnostic imaging centers to perform projection radiography.
Meditronics
Meditronics International House 82 Queens Road Brighton BN1 3XE; UK