Message: Return type of CI_Session_files_driver::open($save_path, $name) should either be compatible with SessionHandlerInterface::open(string $path, string $name): bool, or the #[\ReturnTypeWillChange] attribute should be used to temporarily suppress the notice
Message: Return type of CI_Session_files_driver::close() should either be compatible with SessionHandlerInterface::close(): bool, or the #[\ReturnTypeWillChange] attribute should be used to temporarily suppress the notice
Message: Return type of CI_Session_files_driver::read($session_id) should either be compatible with SessionHandlerInterface::read(string $id): string|false, or the #[\ReturnTypeWillChange] attribute should be used to temporarily suppress the notice
Message: Return type of CI_Session_files_driver::write($session_id, $session_data) should either be compatible with SessionHandlerInterface::write(string $id, string $data): bool, or the #[\ReturnTypeWillChange] attribute should be used to temporarily suppress the notice
Message: Return type of CI_Session_files_driver::destroy($session_id) should either be compatible with SessionHandlerInterface::destroy(string $id): bool, or the #[\ReturnTypeWillChange] attribute should be used to temporarily suppress the notice
Message: Return type of CI_Session_files_driver::gc($maxlifetime) should either be compatible with SessionHandlerInterface::gc(int $max_lifetime): int|false, or the #[\ReturnTypeWillChange] attribute should be used to temporarily suppress the notice
KSPM-A100 is a hand held unit which can be used in two different ways (connectible to PC through USB or the unit itself as a desktop) to meet user’s requirements. It features a large TFT screen to display measured FVC, FEV and PEF values. It displays volume and flow rate charts to support diagnosis. Automated unit shut down in case of no user operation.
Specifications :
Flow range
1 L/s ⁓ 16 L/s
Volume range
10 L
Flow accuracy
± 10 %
Volume Accuracy
± 3 %
Trend
Flow rate – Volume
Volume – time
Measure mode
Infrared
Measures
FVC - Forced Vital Capacity
FEV - Forced Expired Volume in one second PEF - Peak expiratory flow
Operating environment
Temperature: +10 °C ~ +40 °C
Relative humidity: ≤80 %
Atmospheric pressure: 70 kPa~106 kPa
Storage environment
Temperature: -40 °C ~ +55 °C
Relative humidity: ≤ 95 %
Atmospheric pressure: 50 kPa~106 kPa
Working Current
60 mA
Battery
DC 3.7 V ; 820 mAh
Dimension
97 × 89 × 36 mm
Weight
150 g
Features :
Portable ultra-thin model
TFT screen displays clear test result
Respondant’s current condition is displayed by red, yellow and green bar
Repeated measurement of pre analyzed data
Provision of memorizing data
Connectable to PC through USB cable
Rechargeable lithium battery
Applications :
Used to check lung conditions to diagnose chronic respiratory diseases. Applicable for routine analysis in hospital, clinics.
Meditronics
Meditronics International House 82 Queens Road Brighton BN1 3XE; UK