Message: Return type of CI_Session_files_driver::open($save_path, $name) should either be compatible with SessionHandlerInterface::open(string $path, string $name): bool, or the #[\ReturnTypeWillChange] attribute should be used to temporarily suppress the notice
Message: Return type of CI_Session_files_driver::close() should either be compatible with SessionHandlerInterface::close(): bool, or the #[\ReturnTypeWillChange] attribute should be used to temporarily suppress the notice
Message: Return type of CI_Session_files_driver::read($session_id) should either be compatible with SessionHandlerInterface::read(string $id): string|false, or the #[\ReturnTypeWillChange] attribute should be used to temporarily suppress the notice
Message: Return type of CI_Session_files_driver::write($session_id, $session_data) should either be compatible with SessionHandlerInterface::write(string $id, string $data): bool, or the #[\ReturnTypeWillChange] attribute should be used to temporarily suppress the notice
Message: Return type of CI_Session_files_driver::destroy($session_id) should either be compatible with SessionHandlerInterface::destroy(string $id): bool, or the #[\ReturnTypeWillChange] attribute should be used to temporarily suppress the notice
Message: Return type of CI_Session_files_driver::gc($maxlifetime) should either be compatible with SessionHandlerInterface::gc(int $max_lifetime): int|false, or the #[\ReturnTypeWillChange] attribute should be used to temporarily suppress the notice
Syringe pump KSP–B100 is a dual-channel light–weight, infusion device designed for low volume infusion. Equipped with separate LCD screen to display independent flow parameters. Inbuilt software system accurately delivers infusion rate and monitors infusion therapy. Memory log system stores last setting of infusion parameters for fast infusion.
Specifications :
Channel
Dual channel infusion
Volume (VTBI)
0.1 ml – 1999.9 ml
Injection Compliance
Adaptable for 10 syringe sizes
Accuracy
≤ ± 3 %
KVO Rate
0.1 ml/h – 5 ml/h (steps : 0.1 ml/h)
Occlusion System
3 selectable occlusion levels
Infusion Rate
0.1 ml/h ~ 1600 ml/h, increment 0.1ml/h
Syringe Size
Channel 01 : 5 ml / 10 ml / 20ml / 30ml / 50ml Channel 02 : 6 ml / 12 ml / 25 ml / 35 ml / 60 ml
Used in general ward, ICU in hospital to gradually administer intra-venous fluid drug dosage at a predetermined rate through syringe for consistent and effective infusion therapy.