Message: Return type of CI_Session_files_driver::open($save_path, $name) should either be compatible with SessionHandlerInterface::open(string $path, string $name): bool, or the #[\ReturnTypeWillChange] attribute should be used to temporarily suppress the notice
Message: Return type of CI_Session_files_driver::close() should either be compatible with SessionHandlerInterface::close(): bool, or the #[\ReturnTypeWillChange] attribute should be used to temporarily suppress the notice
Message: Return type of CI_Session_files_driver::read($session_id) should either be compatible with SessionHandlerInterface::read(string $id): string|false, or the #[\ReturnTypeWillChange] attribute should be used to temporarily suppress the notice
Message: Return type of CI_Session_files_driver::write($session_id, $session_data) should either be compatible with SessionHandlerInterface::write(string $id, string $data): bool, or the #[\ReturnTypeWillChange] attribute should be used to temporarily suppress the notice
Message: Return type of CI_Session_files_driver::destroy($session_id) should either be compatible with SessionHandlerInterface::destroy(string $id): bool, or the #[\ReturnTypeWillChange] attribute should be used to temporarily suppress the notice
Message: Return type of CI_Session_files_driver::gc($maxlifetime) should either be compatible with SessionHandlerInterface::gc(int $max_lifetime): int|false, or the #[\ReturnTypeWillChange] attribute should be used to temporarily suppress the notice
Syringe pump KSP–A200 is a single-channel light–weight, infusion system designed for low volume infusion. Programmed infusion modes, administer drug volume at specified rate as per patient dosage. Dose titration allows uninterrupted flow during change of flow rate. Real-time pressure sensing with anti-bolus and purge feature assures safe operation.
Specifications :
Channel
Single channel infusion
Volume (VTBI)
0 ml – 9999 ml
Injection Compliance
Adaptable for 6 syringe sizes
Accuracy
≤ ±2 %
KVO Rate
0.01 ml/h – 5 ml/h (steps : 0.01 ml/h)
Occlusion System
12 selectable occlusion levels
Syringe Size
5 ml, 10 ml, 20 ml, 30 ml, 50 ml, 60 ml
Infusion Mode
Rate mode/Time mode, Body weight, TIVA, Relay mode Loading-dose, Ramp up/down, Sequence, Drug library mode, Micro mode
Flow Selection
0.01 ml/h ~ 1500 ml/h, increment 0.01 ml/h
Bolus Rate
0.1 ml/h ~ 1500 ml/h (Auto or Manual bolus control)
Display
4.3-inch colour LCD screen
Battery
Lithium polymer battery 11.1 V 2600 mAh About 12 hours of operation at 5ml/h (< 5 hours of charging)
Memory
Records over 5000 entries for review
Drug library
Database of up to 2000 drugs
Safety
Class I Type CF
Moisture Protection
IP24
Operation
Ambient Temperature: 5 °C to 40 °C Relative Humidity: 20 % to 90 %
Storage
Ambient Temperature: –30 °C to 55 °C Relative Humidity: ≤ 95%
Power Supply
AC : 110 V ~ 240 V, 50/60 Hz DC : 12 V
Dimensions
235 × 90 × 120 mm
Weight
1.7 kgs
Features :
Syringe barrel, alignment and volume detection
Built-in drug database library
Vertically stackable to save storage space
Extensive system memory for review
Nurse call, RS232, USB connectivity
Wi-Fi connectivity (optional)
Comprehensive alarms and reminder with selectable volume control
Applications :
Used in general ward, ICU in hospital to gradually administer intra-venous fluid drug dosage at a predetermined rate through syringe for consistent and effective infusion therapy.