Message: Return type of CI_Session_files_driver::open($save_path, $name) should either be compatible with SessionHandlerInterface::open(string $path, string $name): bool, or the #[\ReturnTypeWillChange] attribute should be used to temporarily suppress the notice
Message: Return type of CI_Session_files_driver::close() should either be compatible with SessionHandlerInterface::close(): bool, or the #[\ReturnTypeWillChange] attribute should be used to temporarily suppress the notice
Message: Return type of CI_Session_files_driver::read($session_id) should either be compatible with SessionHandlerInterface::read(string $id): string|false, or the #[\ReturnTypeWillChange] attribute should be used to temporarily suppress the notice
Message: Return type of CI_Session_files_driver::write($session_id, $session_data) should either be compatible with SessionHandlerInterface::write(string $id, string $data): bool, or the #[\ReturnTypeWillChange] attribute should be used to temporarily suppress the notice
Message: Return type of CI_Session_files_driver::destroy($session_id) should either be compatible with SessionHandlerInterface::destroy(string $id): bool, or the #[\ReturnTypeWillChange] attribute should be used to temporarily suppress the notice
Message: Return type of CI_Session_files_driver::gc($maxlifetime) should either be compatible with SessionHandlerInterface::gc(int $max_lifetime): int|false, or the #[\ReturnTypeWillChange] attribute should be used to temporarily suppress the notice
Surgical Diathermy Machine KSD-B100 is a table-top 300 W HF micro-processor controlled electrosurgical generator which modulates frequency levels to achieve Pure-cut, Blend 1, Blend 2, Spray coag, Soft coag, Bipolar cut and Bipolar coag with pedal shoot audio-visual indicators and error codes. Integrated return electrode monitoring system and power peak system prevents tissue damage. Separate power display and socket for mono-polar cut, mono-polar coag, bipolar cut and bipolar coag.
Specifications :
Power Consumption
300 W
Operating Frequency
416 kHz
Modes
5 Monopolar modes 2 Bipolar modes
Monopolar Cut : Pure Cut
1 W ─ 300 W at 800 Ω load impedance
Monopolar Cut : Blend I
1 W ─ 250 W at 800 Ω load impedance
Monopolar Cut : Blend II
1 W ─ 200 W at 800 Ω load impedance
Monopolar Coag : Contact Coag
1 W ─ 80 W at 800 Ω load impedance
Monopolar Coag : Forced Coag
1 W ─ 120 W at 800 Ω load impedance
Bipolar Coag
1 W ─ 50 W at 200 Ω load impedance
Bipolar Cut
1 W ─ 90 W at 200 Ω load impedance
Power Supply
220 V ± 22 V, 50 Hz ± 1 Hz (110 V±11 V, 60 Hz)
Dimensions
640 x 550 x 300 mm
Weight
16 Kgs
Features :
Pedal and well as control button
Auto-test at power-up
Over-voltage and defibrillator protection circuit
Excellent compatibility with various endoscopy sub-units
Convection refrigeration without ventilation
Error codes and alarms for safety
Applications :
Used in Surgical rooms, OTs for microsurgery, neurosurgery, laparoscopy and other surgeries to make precise cuts with limited blood loss for safe and effective hemostasis during cutaneous incision.
Meditronics
Meditronics International House 82 Queens Road Brighton BN1 3XE; UK