Message: Return type of CI_Session_files_driver::open($save_path, $name) should either be compatible with SessionHandlerInterface::open(string $path, string $name): bool, or the #[\ReturnTypeWillChange] attribute should be used to temporarily suppress the notice
Message: Return type of CI_Session_files_driver::close() should either be compatible with SessionHandlerInterface::close(): bool, or the #[\ReturnTypeWillChange] attribute should be used to temporarily suppress the notice
Message: Return type of CI_Session_files_driver::read($session_id) should either be compatible with SessionHandlerInterface::read(string $id): string|false, or the #[\ReturnTypeWillChange] attribute should be used to temporarily suppress the notice
Message: Return type of CI_Session_files_driver::write($session_id, $session_data) should either be compatible with SessionHandlerInterface::write(string $id, string $data): bool, or the #[\ReturnTypeWillChange] attribute should be used to temporarily suppress the notice
Message: Return type of CI_Session_files_driver::destroy($session_id) should either be compatible with SessionHandlerInterface::destroy(string $id): bool, or the #[\ReturnTypeWillChange] attribute should be used to temporarily suppress the notice
Message: Return type of CI_Session_files_driver::gc($maxlifetime) should either be compatible with SessionHandlerInterface::gc(int $max_lifetime): int|false, or the #[\ReturnTypeWillChange] attribute should be used to temporarily suppress the notice
Surgical Diathermy Machine KSD-A100 is a table-top 350 W RF electrosurgical generator which modulates frequency levels to achieve Pure-cut, 2 variations of Blend, 3 variations of Coagulation and 2 variations in bipolar mode for a smooth cut at minimum tissue damage and effective incision without blood loss. Integrated powerful high frequency generator based control system equipped with smart resistance feedback and automatic output compensation designed to operate as per programmed output modes.
Specifications :
Power Consumption
350 W
Operating Frequency
330 kHz ─ 460 kHz
Modes
6 Monopolar modes 2 Bipolar modes
Monopolar Cut : Pure Cut
1 W ─ 350 W at 500 Ω load impedance
Monopolar Cut : Blend I
1 W ─ 250 W at 500 Ω load impedance
Monopolar Cut : Blend II
1 W ─ 150 W at 500 Ω load impedance
Monopolar Coagulation : Coag I
1 W ─ 120 W at 500 Ω load impedance
Monopolar Coagulation : Coag II
1 W ─ 100 W at 500 Ω load impedance
Monopolar Coagulation : Coag III
1 W ─ 50 W at 500 Ω load impedance
Bipolar I
1 W ─ 150 W at 100 Ω load impedance
Bipolar II
1 W ─ 100 W at 100 Ω load impedance
Memory Functions
10 Memory programs
Pressure Range
50 kPa ─ 106 kPa
Relative Humidity Range
≤ 80%
Operating Temperature
10 °C ─ 40 °C
Power Supply
220 V ─ 110 V 50/60 Hz
Dimensions
430 x 380 x 165 mm
Weight
7 Kgs
Features :
3 monopolar cut modes
3 monopolar coagulation modes
Bipolar vessel sealing mode
Bipolar coagulation mode
Auto-test at power-up
Excellent compatibility with various endoscopy sub-units
10 memory settings with memory back-up
Alarm for Improper or Inadequate electrode contact
Applications :
Used in surgical rooms, OTs for microsurgery, neurosurgery, laparoscopy and other surgeries to make precise cuts with limited blood loss for safe and effective hemostasis during cutaneous incision.