Message: Return type of CI_Session_files_driver::open($save_path, $name) should either be compatible with SessionHandlerInterface::open(string $path, string $name): bool, or the #[\ReturnTypeWillChange] attribute should be used to temporarily suppress the notice
Message: Return type of CI_Session_files_driver::close() should either be compatible with SessionHandlerInterface::close(): bool, or the #[\ReturnTypeWillChange] attribute should be used to temporarily suppress the notice
Message: Return type of CI_Session_files_driver::read($session_id) should either be compatible with SessionHandlerInterface::read(string $id): string|false, or the #[\ReturnTypeWillChange] attribute should be used to temporarily suppress the notice
Message: Return type of CI_Session_files_driver::write($session_id, $session_data) should either be compatible with SessionHandlerInterface::write(string $id, string $data): bool, or the #[\ReturnTypeWillChange] attribute should be used to temporarily suppress the notice
Message: Return type of CI_Session_files_driver::destroy($session_id) should either be compatible with SessionHandlerInterface::destroy(string $id): bool, or the #[\ReturnTypeWillChange] attribute should be used to temporarily suppress the notice
Message: Return type of CI_Session_files_driver::gc($maxlifetime) should either be compatible with SessionHandlerInterface::gc(int $max_lifetime): int|false, or the #[\ReturnTypeWillChange] attribute should be used to temporarily suppress the notice
Operating Table KOT-A100 features high density sponge in one piece with no seam, mattress is wrapped with artificial leather. It is incorporated with high quality motor without noise formation and foot treadle brake device for easy movement of operating table. Separate section for legs and it uses spring gas control for counterbalance (support)
Specifications :
Length
2000 ± 50 mm
Width
500 ± 20 mm
Adjustable height (Min to Max)
( 750 to 1000 ) ±50 mm
Trendelenburg
≥ 25 °
Reverse Trendelenburg
≥ 35 °
Lateral tilt
≥ 15 °
Head section folds upward
≥ 40 °
Head section folds downward
≥ 90 °
Leg section folds downward
≥ 90 °
Leg section folds outward
≥ 90 °
Back section fold upward
≥ 45 °
Back section fold downward
≥ 20 °
Waist lifting
≥ 100 mm
Power supply
220 V (AC) ± 10 % ; 50 Hz
Input power
300 VA
Features :
Electrically controlled operation
Adjustable height
Trendelenburg and lateral tilt
Base seat and upright column covers made up of stainless steel
Panel control and remote control
Head and leg section folding
Back section folding
Long life-span motor
Applications :
Used in hospitals, operating room to carry out surgeries on patients.
Meditronics