Message: Return type of CI_Session_files_driver::open($save_path, $name) should either be compatible with SessionHandlerInterface::open(string $path, string $name): bool, or the #[\ReturnTypeWillChange] attribute should be used to temporarily suppress the notice
Message: Return type of CI_Session_files_driver::close() should either be compatible with SessionHandlerInterface::close(): bool, or the #[\ReturnTypeWillChange] attribute should be used to temporarily suppress the notice
Message: Return type of CI_Session_files_driver::read($session_id) should either be compatible with SessionHandlerInterface::read(string $id): string|false, or the #[\ReturnTypeWillChange] attribute should be used to temporarily suppress the notice
Message: Return type of CI_Session_files_driver::write($session_id, $session_data) should either be compatible with SessionHandlerInterface::write(string $id, string $data): bool, or the #[\ReturnTypeWillChange] attribute should be used to temporarily suppress the notice
Message: Return type of CI_Session_files_driver::destroy($session_id) should either be compatible with SessionHandlerInterface::destroy(string $id): bool, or the #[\ReturnTypeWillChange] attribute should be used to temporarily suppress the notice
Message: Return type of CI_Session_files_driver::gc($maxlifetime) should either be compatible with SessionHandlerInterface::gc(int $max_lifetime): int|false, or the #[\ReturnTypeWillChange] attribute should be used to temporarily suppress the notice
Mobile X-ray machine KMX-B101 is an advanced x-ray imaging modality designed for better mobility and manageability during intra-hospital transit. System is equipped with 50 pre-set exposure programs with automatic back-up memory and multiple protection functions for safer use. Automatic self-test setting and alarming reduces need for maintenance. Proximal as well as remote accessibility controllers make it more versatile to use.
Specifications :
Inverter Frequency
50 kHz
Tube Voltage
40 kV – 120 kV (interval 1 kV)
Operational Access
Wired/Wireless Control
Current
1.0–180 mAs (46 steps)
Power Rating
5 kVA
Internal Resistance
≤ 1 Ω
Exposure Parameters
Voltage
Current
Radiographic Density
40 kV - 49 kV
100 mA
1 mAs - 180 mAs
50 kV - 59 kV
77 mA
1 mAs - 140 mAs
60 kV - 69 kV
64 mA
1 mAs - 125 mAs
70 kV - 79 kV
55 mA
1 mAs - 110 mAs
80 kV - 89 kV
49 mA
1 mAs - 100 mAs
90 kV - 99 kV
44 mA
1 mAs - 80 mAs
100 kV - 109 kV
32 mA
1 mAs - 63 mAs
110 kV - 120 kV
25 mA
1 mAs - 50 mAs
Power Supply
Voltage : 220 V ±10% Frequency : 50Hz
Built–in Battery
Rechargeable Lithium
Dimensions
1500 x 750 x 1850 mm
Weight
355 Kgs
Features :
High frequency X-ray generation
High quality X-ray monolight technology
Exposure current: 1.0-180mAs (46 steps)
50 built-in exposure control programs
Accurate X-ray penetration
Flexible and easy source orientation
Symmetrical collimator
Mobile table (optional)
Built-in rechargeable battery
Applications :
Used throughout the hospital from in-patient, to NICU, operating room, and emergency room as well as polyclinics to perform projection radiography readily on bedbound or critical patients for convenience.
Meditronics