Message: Return type of CI_Session_files_driver::open($save_path, $name) should either be compatible with SessionHandlerInterface::open(string $path, string $name): bool, or the #[\ReturnTypeWillChange] attribute should be used to temporarily suppress the notice
Message: Return type of CI_Session_files_driver::close() should either be compatible with SessionHandlerInterface::close(): bool, or the #[\ReturnTypeWillChange] attribute should be used to temporarily suppress the notice
Message: Return type of CI_Session_files_driver::read($session_id) should either be compatible with SessionHandlerInterface::read(string $id): string|false, or the #[\ReturnTypeWillChange] attribute should be used to temporarily suppress the notice
Message: Return type of CI_Session_files_driver::write($session_id, $session_data) should either be compatible with SessionHandlerInterface::write(string $id, string $data): bool, or the #[\ReturnTypeWillChange] attribute should be used to temporarily suppress the notice
Message: Return type of CI_Session_files_driver::destroy($session_id) should either be compatible with SessionHandlerInterface::destroy(string $id): bool, or the #[\ReturnTypeWillChange] attribute should be used to temporarily suppress the notice
Message: Return type of CI_Session_files_driver::gc($maxlifetime) should either be compatible with SessionHandlerInterface::gc(int $max_lifetime): int|false, or the #[\ReturnTypeWillChange] attribute should be used to temporarily suppress the notice
Mobile X-ray machine KMX-A101 is an advanced X-ray imaging modality designed to be highly efficient and portable medical imaging solution for intra-departmental transport. Equipped with single focus full wave rectification for stable and precise-controlled operation. Accurate X-ray beam focusing results in dose-efficient X-ray and enhances image quality. Equipped with high voltage protection circuit for user as well as patient.
Specifications :
Focal Distance
350 x 350 mm
Source Head Range
520 mm - 1880 mm
Exposure DC Voltage
100 kV ; 50 kV - 100 kV
Exposure DC Current
35 A (instant)
Exposure Time
0.08 s - 6.32 s
Tube Focus
4.3 x 4.3 mm
Collimator Film (max)
650 mm
Spot-film Tube Current
150 mA (fixed)
Column Angular Range
±45°
Spot Focus
16 mA, 32mA, 63mA, 100mA
Power Supply
Voltage : 180 V - 240 V Frequency : 50 Hz
Dimensions
1500 x 800 x 1500 mm
Weight
150 Kgs
Features :
Standard frequency X-ray generator
High quality imaging
SCM control technology
8 Pre-defined exposure control
High voltage SCR safety circuit
Cantilever head source structure
Applications :
Used throughout the hospital from in-patient, to NICU, operating room, and emergency room as well as polyclinics to perform projection radiography readily on bedbound or critical patients for convenience.
Meditronics