Message: Return type of CI_Session_files_driver::open($save_path, $name) should either be compatible with SessionHandlerInterface::open(string $path, string $name): bool, or the #[\ReturnTypeWillChange] attribute should be used to temporarily suppress the notice
Message: Return type of CI_Session_files_driver::close() should either be compatible with SessionHandlerInterface::close(): bool, or the #[\ReturnTypeWillChange] attribute should be used to temporarily suppress the notice
Message: Return type of CI_Session_files_driver::read($session_id) should either be compatible with SessionHandlerInterface::read(string $id): string|false, or the #[\ReturnTypeWillChange] attribute should be used to temporarily suppress the notice
Message: Return type of CI_Session_files_driver::write($session_id, $session_data) should either be compatible with SessionHandlerInterface::write(string $id, string $data): bool, or the #[\ReturnTypeWillChange] attribute should be used to temporarily suppress the notice
Message: Return type of CI_Session_files_driver::destroy($session_id) should either be compatible with SessionHandlerInterface::destroy(string $id): bool, or the #[\ReturnTypeWillChange] attribute should be used to temporarily suppress the notice
Message: Return type of CI_Session_files_driver::gc($maxlifetime) should either be compatible with SessionHandlerInterface::gc(int $max_lifetime): int|false, or the #[\ReturnTypeWillChange] attribute should be used to temporarily suppress the notice
Intensive Care Ventilator KVI- A102 is designed to meet the needs of clinical respiratory management for Infants with respiratory disorder. It has a provision to work with innovative ventilation modes like constant flow, pressure limit and time cycle ventilation.
Specifications :
Tidal Volume
10 ml ~ 300 ml
Standard Ventilation Mode
CMV, IMV, CPAP, Manual
Application
Pediatric
Inspiratory Flow
3 L/min ~ 20 L/min
Respiration rate
1 bpm ~120 bpm
I:E Ratio
1:1 to 1:3
Oxygen Concentration
21 % ~ 100 %
Pressure trigger Range
-1.0 to 0 kPa
Flow Trigger Range
0 to 10 L
PEEP Type
Pneumatic Driven, Electronic Control
Inspiratory Pause Time
0.2 s ~ 3.0 s
Maximum Security Pressure
≤ 10 kPa
PEEP Range
0 kPa ~2.0 kPa
Max Ventilation Volume
> 5 L/min
Input Pressure
0.15 MPa ~ 0.3 Mpa
Inspiratory Pressure
1 kPa ~ 9 kPa
Features :
Innovative ventilation mode
Safe and Reliable
Compact and Reasonable
Applications :
Used in operating rooms, NICU, and other departments for pulmonary life-support during acute lung injury or respiratory distress which result in inadequate oxygenation or ventilation inability to protect the airway fluids.