Message: Return type of CI_Session_files_driver::open($save_path, $name) should either be compatible with SessionHandlerInterface::open(string $path, string $name): bool, or the #[\ReturnTypeWillChange] attribute should be used to temporarily suppress the notice
Message: Return type of CI_Session_files_driver::close() should either be compatible with SessionHandlerInterface::close(): bool, or the #[\ReturnTypeWillChange] attribute should be used to temporarily suppress the notice
Message: Return type of CI_Session_files_driver::read($session_id) should either be compatible with SessionHandlerInterface::read(string $id): string|false, or the #[\ReturnTypeWillChange] attribute should be used to temporarily suppress the notice
Message: Return type of CI_Session_files_driver::write($session_id, $session_data) should either be compatible with SessionHandlerInterface::write(string $id, string $data): bool, or the #[\ReturnTypeWillChange] attribute should be used to temporarily suppress the notice
Message: Return type of CI_Session_files_driver::destroy($session_id) should either be compatible with SessionHandlerInterface::destroy(string $id): bool, or the #[\ReturnTypeWillChange] attribute should be used to temporarily suppress the notice
Message: Return type of CI_Session_files_driver::gc($maxlifetime) should either be compatible with SessionHandlerInterface::gc(int $max_lifetime): int|false, or the #[\ReturnTypeWillChange] attribute should be used to temporarily suppress the notice
Intensive Care Ventilator KVI- A101 is a respiratory ventilator unit for invasive artificial respiration. Built-in provision for self-testing and calibration. The device is made up of high configuration intelligent control system that allows changes to be made according to user requirements.
Specifications :
Tidal Volume
20 ml ~ 500 ml
Standard Ventilation Mode
VCV, SIMV, PSV, PCV, CPAP, Manual, SIGH
Application
Adult/ Pediatric Invasive
Pressure Range
5 mbar ~ 80 mbar
Respiration rate range
1 bpm ~ 99 bpm
1 bpm ~ 40 bpm under SIMV
I:E Ratio
4:1 to 1:8
Oxygen Concentration
21 % ~ 100 %
Pressure trigger Range
-20 to 20 cmH2O
PEEP Type
Integrated, Electronic Control
PEEP Range
0 to 30 cmH2O
Gas Supply
O2, Air ( 280 kPa ~ 600 kPa )
Alarm
Visual : No tidal volume, MV, Paw, FiO2 limitation O2, Air failure, AC power failure, low back up
Audio: No tidal volume, MV, Paw, FiO2 limitation
Display
12.1” Color LCD
Graphic Display
Waveforms of P-T, F-T, V-T
Operating Temperature
5 °C ~ 40 °C
Storage Temperature
-10 °C to 40 °C
Relative Humidity
≤ 80 %
Atmospheric Pressure
96 kPa ~ 104 kPa
Battery
Lead acid 12V, 4Ah (120 mins run time)
Output Pressure
0.4 mPa ± 0.1 mPa
Noise
≤ 50 dB
Power Supply
AC 220 V ± 10 %, 50 Hz ± 2 %
Dimension
450 x 550 x 1400 mm
Weight
65 kgs
Features :
Large screen display for parameter visualization and control
Desirable display color schemes
Self-testing and calibration
Air compressor support (Optional)
Applications :
Used in operating rooms, surgical care wards, intensive care unit, and other departments for pulmonary life-support during acute lung injury or respiratory distress which result in inadequate oxygenation or ventilation inability to protect the airway fluids.
Meditronics
Meditronics International House 82 Queens Road Brighton BN1 3XE; UK