Message: Return type of CI_Session_files_driver::open($save_path, $name) should either be compatible with SessionHandlerInterface::open(string $path, string $name): bool, or the #[\ReturnTypeWillChange] attribute should be used to temporarily suppress the notice
Message: Return type of CI_Session_files_driver::close() should either be compatible with SessionHandlerInterface::close(): bool, or the #[\ReturnTypeWillChange] attribute should be used to temporarily suppress the notice
Message: Return type of CI_Session_files_driver::read($session_id) should either be compatible with SessionHandlerInterface::read(string $id): string|false, or the #[\ReturnTypeWillChange] attribute should be used to temporarily suppress the notice
Message: Return type of CI_Session_files_driver::write($session_id, $session_data) should either be compatible with SessionHandlerInterface::write(string $id, string $data): bool, or the #[\ReturnTypeWillChange] attribute should be used to temporarily suppress the notice
Message: Return type of CI_Session_files_driver::destroy($session_id) should either be compatible with SessionHandlerInterface::destroy(string $id): bool, or the #[\ReturnTypeWillChange] attribute should be used to temporarily suppress the notice
Message: Return type of CI_Session_files_driver::gc($maxlifetime) should either be compatible with SessionHandlerInterface::gc(int $max_lifetime): int|false, or the #[\ReturnTypeWillChange] attribute should be used to temporarily suppress the notice
Infant Incubator KII-A102 is a microprocessor-controlled advanced thermoregulation system. Sensor-based dedicated air thermo-control allows temperature regulation. External knobs adjust inclination of the bassinet platform for smooth positioning of the infant.
Specifications :
Control System
Air-temp control
Display
LED display
Air Temperature Control range
25°C ~ 37°C
Temperature Variability
≤ 0.5°C
Temperature Uniformity (On Mattress)
≤ 0.8°C
Access ports
2 ports, 4 windows
Temperature Resolution
0.1°C
Temperature Accuracy
± 0.3°C
Humidity Accuracy
± 5% RH
Water Tank Capacity
1000ml
Alarms
Audio-visual indicators. Air-temperature deviation, Over Air temp, Sensor fail, Water shortage in tank
Mattress Size
630 × 340 mm
Bassinet Tilt
± 12° continuous tilt
Power Supply
110 V ~ 120 V, 50/60 Hz
220 V ~ 240 V, 50/60 Hz
Data Transfer
RS-232
Dimensions
1160 x 720 x 1650 mm
Weight
75 Kgs
Features :
Single sensor temperature control
3-level priority alarms
Integrated double phototherapy unit (optional)
Applications :
Used in NICU, neonatal-care wards for critical or premature neonates to maintain a proper temperature and humidity during post-natal weaning period.
Meditronics
Meditronics International House 82 Queens Road Brighton BN1 3XE; UK