Message: Return type of CI_Session_files_driver::open($save_path, $name) should either be compatible with SessionHandlerInterface::open(string $path, string $name): bool, or the #[\ReturnTypeWillChange] attribute should be used to temporarily suppress the notice
Message: Return type of CI_Session_files_driver::close() should either be compatible with SessionHandlerInterface::close(): bool, or the #[\ReturnTypeWillChange] attribute should be used to temporarily suppress the notice
Message: Return type of CI_Session_files_driver::read($session_id) should either be compatible with SessionHandlerInterface::read(string $id): string|false, or the #[\ReturnTypeWillChange] attribute should be used to temporarily suppress the notice
Message: Return type of CI_Session_files_driver::write($session_id, $session_data) should either be compatible with SessionHandlerInterface::write(string $id, string $data): bool, or the #[\ReturnTypeWillChange] attribute should be used to temporarily suppress the notice
Message: Return type of CI_Session_files_driver::destroy($session_id) should either be compatible with SessionHandlerInterface::destroy(string $id): bool, or the #[\ReturnTypeWillChange] attribute should be used to temporarily suppress the notice
Message: Return type of CI_Session_files_driver::gc($maxlifetime) should either be compatible with SessionHandlerInterface::gc(int $max_lifetime): int|false, or the #[\ReturnTypeWillChange] attribute should be used to temporarily suppress the notice
Holter Monitor KHM-A100 is a 24-hour ambulatory ECG recorder designed to record real-time ECG. System is equipped with OLED screen for waveform preview, record review and event marking. Integrated frequency filters allow anti-jamming and aseismic capability for error free waveforms. Data storage up to 2GB using TF card enables original data to be stored without compression. System performs 12-lead synchro-analysis for distortion-free QRS detection.
ST segment analysis , HRT analysis, T-Wave alternation,QTD (QT dispersion) VCG (vector cardiogram), VLP (ventricular late potential) and TVCG (time vector cardiogram) analysis
Heart-rate Analysis
Short range : 5 minutes Long range : 1 hour Continuous : 24 hours
Sampling
Sampling Accuracy : 12 Bit Rate of Sampling : 10 kHz
Batteries
2 AA batteries
Interface
USB 2.0
Scale Voltage
1mV ± 5%
Noise
≤ 30µV
CMRR
≥ 60 dB
Time Constant
≥ 3.2 s
Polarization voltage
± 300 mV (DC)
Dimension
111 x 60 x 25 mm
Weight
105 g
Features :
12-lead synchronous acquisition
Fast review analysis
Accurate and Quick report generation
More than 10 pre-defined modules and user-defined impulse tracking for premature conduction impulses
ECG-analysis function
Predictive arrhythmia analysis module
Predictive pacing analysis module
Flexible channel selection
Applications :
Used in cardiology center to diagnose and detect symptoms of various heart disease and arrhythmias, determine a patient’s response to drug therapy, function of pacemaker and reveal trends or changes in heart function during normal routine activities.
Meditronics
Meditronics International House 82 Queens Road Brighton BN1 3XE; UK