Message: Return type of CI_Session_files_driver::open($save_path, $name) should either be compatible with SessionHandlerInterface::open(string $path, string $name): bool, or the #[\ReturnTypeWillChange] attribute should be used to temporarily suppress the notice
Message: Return type of CI_Session_files_driver::close() should either be compatible with SessionHandlerInterface::close(): bool, or the #[\ReturnTypeWillChange] attribute should be used to temporarily suppress the notice
Message: Return type of CI_Session_files_driver::read($session_id) should either be compatible with SessionHandlerInterface::read(string $id): string|false, or the #[\ReturnTypeWillChange] attribute should be used to temporarily suppress the notice
Message: Return type of CI_Session_files_driver::write($session_id, $session_data) should either be compatible with SessionHandlerInterface::write(string $id, string $data): bool, or the #[\ReturnTypeWillChange] attribute should be used to temporarily suppress the notice
Message: Return type of CI_Session_files_driver::destroy($session_id) should either be compatible with SessionHandlerInterface::destroy(string $id): bool, or the #[\ReturnTypeWillChange] attribute should be used to temporarily suppress the notice
Message: Return type of CI_Session_files_driver::gc($maxlifetime) should either be compatible with SessionHandlerInterface::gc(int $max_lifetime): int|false, or the #[\ReturnTypeWillChange] attribute should be used to temporarily suppress the notice
Haematology Analyser KHA-A200 is a fully-automated 20 parameter 3-part WBC differentiation benchtop blood cell counter unit. System features LCD display, error alarms, 2 counting modes for whole blood and prediluted samples. Internal software system detects failures, enables calibration facility, QC testing and steers automatic probe wash to prevent sample carryover phenomenon. Safe reagents ensure eco-friendly operational standards to be maintained.
Specifications :
Type
Fully automated 3-part differential system
Throughput
60 samples/hr
Testing Parameters
WBC, LY, LY%, MO, MO%,GR,GR%,RBC,HGB,HCT, MCV,RDW-SD, RDWCV, MCH, MCHC, PLT, MPV, PCT, PDW with Histograms for WBC, RBC and PLT.
Used in diagnostic laboratories, pathological diagnostic centers to characterize blood cells, determine their count and cell volume for in-vitro pathological diagnosis of blood samples to meet qualifying performance requirements and standardized results for multiple sample analysis.
Meditronics
Meditronics International House 82 Queens Road Brighton BN1 3XE; UK