Message: Return type of CI_Session_files_driver::open($save_path, $name) should either be compatible with SessionHandlerInterface::open(string $path, string $name): bool, or the #[\ReturnTypeWillChange] attribute should be used to temporarily suppress the notice
Message: Return type of CI_Session_files_driver::close() should either be compatible with SessionHandlerInterface::close(): bool, or the #[\ReturnTypeWillChange] attribute should be used to temporarily suppress the notice
Message: Return type of CI_Session_files_driver::read($session_id) should either be compatible with SessionHandlerInterface::read(string $id): string|false, or the #[\ReturnTypeWillChange] attribute should be used to temporarily suppress the notice
Message: Return type of CI_Session_files_driver::write($session_id, $session_data) should either be compatible with SessionHandlerInterface::write(string $id, string $data): bool, or the #[\ReturnTypeWillChange] attribute should be used to temporarily suppress the notice
Message: Return type of CI_Session_files_driver::destroy($session_id) should either be compatible with SessionHandlerInterface::destroy(string $id): bool, or the #[\ReturnTypeWillChange] attribute should be used to temporarily suppress the notice
Message: Return type of CI_Session_files_driver::gc($maxlifetime) should either be compatible with SessionHandlerInterface::gc(int $max_lifetime): int|false, or the #[\ReturnTypeWillChange] attribute should be used to temporarily suppress the notice
Haematology Analyser KHA-A100 is a fully-automated 20 parameter 3-part WBC differentiation benchtop blood cell counter unit. System features color LCD display, large storage memory, error alarms, 2 counting modes for whole blood and prediluted samples. Internal software system detects mechanical failures, enables calibration facility as well as advanced QC testing for standardized operation at reduced routine servicing. System is equipped with back-flush as well as blockage removal facility to improve hygiene control.
Specifications :
Type
Fully automated 3-part differential system
Throughput
60 samples/hr
Testing Parameters
WBC, LYM#, MON#, GRA#, LYM%,MON%, GRA%, RBC, HGB, MCHC, MCH, MCV, PDW, RDW-CV, RDW-SD, HCT, PLT,MPV, P-LCR, PCT with Histograms for WBC, RBC and PLT.
Used in diagnostic laboratories, pathological diagnostic centers to characterize blood cells, determine their count and cell volume for in-vitro pathological diagnosis of blood samples to meet qualifying performance requirements and standardized results for multiple sample analysis.