Message: Return type of CI_Session_files_driver::open($save_path, $name) should either be compatible with SessionHandlerInterface::open(string $path, string $name): bool, or the #[\ReturnTypeWillChange] attribute should be used to temporarily suppress the notice
Message: Return type of CI_Session_files_driver::close() should either be compatible with SessionHandlerInterface::close(): bool, or the #[\ReturnTypeWillChange] attribute should be used to temporarily suppress the notice
Message: Return type of CI_Session_files_driver::read($session_id) should either be compatible with SessionHandlerInterface::read(string $id): string|false, or the #[\ReturnTypeWillChange] attribute should be used to temporarily suppress the notice
Message: Return type of CI_Session_files_driver::write($session_id, $session_data) should either be compatible with SessionHandlerInterface::write(string $id, string $data): bool, or the #[\ReturnTypeWillChange] attribute should be used to temporarily suppress the notice
Message: Return type of CI_Session_files_driver::destroy($session_id) should either be compatible with SessionHandlerInterface::destroy(string $id): bool, or the #[\ReturnTypeWillChange] attribute should be used to temporarily suppress the notice
Message: Return type of CI_Session_files_driver::gc($maxlifetime) should either be compatible with SessionHandlerInterface::gc(int $max_lifetime): int|false, or the #[\ReturnTypeWillChange] attribute should be used to temporarily suppress the notice
Dental X-ray KDX-A200 is a portable intra-oral imaging modality which uses high frequency DC X-ray generators for good radiographic contrast at minimal dosage. Graphic LCD screen displays various indicative parameters for exposure control and alarms. Touch key user-interface for customized exposure. Incorporated components have vacuum insulation and stereotype sealed protection for stable and extended life of equipment.
Specifications :
Tube Voltage
60 kV
Tube Current
1 mA
Exposure Time
0.02 s – 2 s
Tube Focus
0.3 x 0.3 mm
Configuration
Portable
Battery
DC : 14.8 V, 6400 mA
Charger Output
DC : 16.8 V
Charger Input
AC 100 V-240 V ±10 %
Frequency
30 kHz
Power Rating
60 VA
SSD (Source Skin Distance)
130 mm
Dimension
138 x 165 x 185 mm
Weight
2.2 Kgs
Features :
Micro focus technology
Digital control panel
Accurate and quick imaging
Pneumatic controlled seat – mobile or fixed
Trusted tube quality
Applications :
Used in dental clinics for dental X-ray imaging to reveal impacted teeth, advanced periodontal disease, sinusitis and to plan treatment dentures, braces, extractions or implants