Message: Return type of CI_Session_files_driver::open($save_path, $name) should either be compatible with SessionHandlerInterface::open(string $path, string $name): bool, or the #[\ReturnTypeWillChange] attribute should be used to temporarily suppress the notice
Message: Return type of CI_Session_files_driver::close() should either be compatible with SessionHandlerInterface::close(): bool, or the #[\ReturnTypeWillChange] attribute should be used to temporarily suppress the notice
Message: Return type of CI_Session_files_driver::read($session_id) should either be compatible with SessionHandlerInterface::read(string $id): string|false, or the #[\ReturnTypeWillChange] attribute should be used to temporarily suppress the notice
Message: Return type of CI_Session_files_driver::write($session_id, $session_data) should either be compatible with SessionHandlerInterface::write(string $id, string $data): bool, or the #[\ReturnTypeWillChange] attribute should be used to temporarily suppress the notice
Message: Return type of CI_Session_files_driver::destroy($session_id) should either be compatible with SessionHandlerInterface::destroy(string $id): bool, or the #[\ReturnTypeWillChange] attribute should be used to temporarily suppress the notice
Message: Return type of CI_Session_files_driver::gc($maxlifetime) should either be compatible with SessionHandlerInterface::gc(int $max_lifetime): int|false, or the #[\ReturnTypeWillChange] attribute should be used to temporarily suppress the notice
Dental X-ray KDX-A100 is an intra-oral imaging modality which uses fine focus X-ray generators and small focal spot for optimum penetration power, good radiographic contrast at minimal dosage. Digital one-touch operation and microprocessor based exposure control along with low voltage alarming and high voltage protection ensures stable, efficient and low radiation output consistently. Micro-focus technology ensures clear image and accurate diagnosis.
Specifications :
Tube Voltage
60 kV
Tube Current
8 mA
Exposure Time
0.2 s – 4 s
Tube Focus
0.8 mm
Configuration
Wall Mounted unit
Leak Radiation
One meter ≤ 0.002 mGy/h (National standard:0.25mGy/h)
Total Filtration
2.5 mm Al
Charger Input
AC : 220 V ± 10%, 50 Hz ,1 kVA
SSD (Source Skin Distance)
20 cm
Weight
35 Kgs
Features :
Micro focus technology
Digital control panel
Wall mounted unit
Accurate and quick imaging
Trusted X-ray tube quality
Applications :
Used in dental clinics for dental X-ray imaging to reveal impacted teeth, advanced periodontal disease, sinusitis and to plan treatment dentures, braces, extractions or implants
Meditronics
Meditronics International House 82 Queens Road Brighton BN1 3XE; UK