Message: Return type of CI_Session_files_driver::open($save_path, $name) should either be compatible with SessionHandlerInterface::open(string $path, string $name): bool, or the #[\ReturnTypeWillChange] attribute should be used to temporarily suppress the notice
Message: Return type of CI_Session_files_driver::close() should either be compatible with SessionHandlerInterface::close(): bool, or the #[\ReturnTypeWillChange] attribute should be used to temporarily suppress the notice
Message: Return type of CI_Session_files_driver::read($session_id) should either be compatible with SessionHandlerInterface::read(string $id): string|false, or the #[\ReturnTypeWillChange] attribute should be used to temporarily suppress the notice
Message: Return type of CI_Session_files_driver::write($session_id, $session_data) should either be compatible with SessionHandlerInterface::write(string $id, string $data): bool, or the #[\ReturnTypeWillChange] attribute should be used to temporarily suppress the notice
Message: Return type of CI_Session_files_driver::destroy($session_id) should either be compatible with SessionHandlerInterface::destroy(string $id): bool, or the #[\ReturnTypeWillChange] attribute should be used to temporarily suppress the notice
Message: Return type of CI_Session_files_driver::gc($maxlifetime) should either be compatible with SessionHandlerInterface::gc(int $max_lifetime): int|false, or the #[\ReturnTypeWillChange] attribute should be used to temporarily suppress the notice
Dialyzer Reprocessing Machine KDR-A101 is an advanced dialyzer reprocessing unit equipped with touch panel control LCD screen to select various functional settings for automated reprocessing. Specialized concentration detection system delivers optimal amount of disinfectant and ensures safe disinfection process. The reprocessing system complies with several quality factors to achieve accurate ultra-filtration standards at minimal water usage.
Specifications :
Cycle time
12 minutes per cycle
Volume test range
0 mL to 150 mL ( ±3 % )
Operational Workstation
Double
Minimum Water inlet Flow
1.5 L/min
Water input temperature
10 °C to 40 °C
Water input pressure
0.15 MPa to 0.35 MPa
Power consumption
150 W
Operation temperature
5 °C to 40 °C
Storage temperature
5 °C to 40 °C
Power supply
AC 220 V ±10 %, 50/60 Hz
Dimensions
480 ×380 ×580mm
Weight
35 Kgs
Features :
Automated reprocessing cycle: 12 minutes per cycle
Touch screen LCD
Operational Workstation : Double
Accurate TCV and blood leak test
Safe and automatic disinfectant dilution
Comprehensive data management system
Data record and print function
Effective cross-contamination control
Troubleshoot tips and alarms
Reduced water loss (< 8 L/dialyzer)
Applications :
Used in nephrology (AKD) departments in hospitals or Kidney dialysis centers to effectively automate reprocessing activities detect blood volume as well as inspect for dialyzer compliance with hospital infection-control measures for reuse of the dialyzer unit and provide recorded patient data for record keeping and quality control.