Message: Return type of CI_Session_files_driver::open($save_path, $name) should either be compatible with SessionHandlerInterface::open(string $path, string $name): bool, or the #[\ReturnTypeWillChange] attribute should be used to temporarily suppress the notice
Message: Return type of CI_Session_files_driver::close() should either be compatible with SessionHandlerInterface::close(): bool, or the #[\ReturnTypeWillChange] attribute should be used to temporarily suppress the notice
Message: Return type of CI_Session_files_driver::read($session_id) should either be compatible with SessionHandlerInterface::read(string $id): string|false, or the #[\ReturnTypeWillChange] attribute should be used to temporarily suppress the notice
Message: Return type of CI_Session_files_driver::write($session_id, $session_data) should either be compatible with SessionHandlerInterface::write(string $id, string $data): bool, or the #[\ReturnTypeWillChange] attribute should be used to temporarily suppress the notice
Message: Return type of CI_Session_files_driver::destroy($session_id) should either be compatible with SessionHandlerInterface::destroy(string $id): bool, or the #[\ReturnTypeWillChange] attribute should be used to temporarily suppress the notice
Message: Return type of CI_Session_files_driver::gc($maxlifetime) should either be compatible with SessionHandlerInterface::gc(int $max_lifetime): int|false, or the #[\ReturnTypeWillChange] attribute should be used to temporarily suppress the notice
Mobile C-Arm X-ray KCX-A100 is a compact multi-configurational x-ray imaging surgical modality. System incorporates advanced 9” image intensifier with multiple imaging tools for advanced and optimized workflow. Extended orbital rotation with dual focus larger field of view improves image quality. Pre-defined positional configurations assist greater coverage on areas typically considered out of reach.
Specifications :
X-Ray Generator
Frequency 40 kHz
Power Capacity 3.5 kW
Tube Current
X-ray : 20 mA - 63 mA
Fluoroscopy : 8 mA
Tube Voltage
40 kV ~ 110 kV
Exposure Factor
1 ~ 125 mAs
X-ray Tube Configuration
Stationary anode with dual focus
Video Monitoring System
Monitor : 14" High definition CRT with ±135°
rotation Vidicon Tube : 0.47 MP Ultra Low-Illumination CCD
Detector
9" Image Intensifier with micro-groove grid
X-ray Tube Thermal Capacity
650 kJ
Operation Interface
Graphic LCD touch screen along with portable hand-held controller
Collimator
Motorized multi-leaf collimator
Fluoroscopy Mode : Automatic
Tube voltage : 40 kV ~ 110 kV adjust automatically
Tube current: 0.3 mA ~ 4 mA adjust automatically
Fluoroscopy Mode : Manual
Tube voltage 40 kV ~ 110 kV continuous
Tube current: 0.3 mA~4 mA continuous
Fluoroscopy Mode : Pulsed
Tube voltage 40 kV ~ 110 kV continuous
Tube current: 4.1 mA~8 mA continuous
C-Arm Positioning Angles
Forward and backward movement: 200m
Revolution around Horizontal axis: ± 180°
Revolution around Vertical axis: ± 15º
Orbital Rotation: 120° (+90°~ -30°)
Focus Control
Focus screen distance: 960 mm
Small focus: 0.6 and Large focus: 1.5
Plate Holder
8″ x 10″ / 10″ x 12″
Dimensions
2440 x 1100 x 1420 mm
Weight
353 Kgs
Features :
10-inch high resolution screen
Digital beam-forming technology
Pseudo-colour imaging
Sharp high definition imaging
Real-time depth adjustability
Adjustable focus control and positioning
Applications :
Used in OTs, cardiac OT, orthopedics, general surgery for fluoroscopy or real-time image-guided surgical navigation during implant placement, DSA, etc.