Message: Return type of CI_Session_files_driver::open($save_path, $name) should either be compatible with SessionHandlerInterface::open(string $path, string $name): bool, or the #[\ReturnTypeWillChange] attribute should be used to temporarily suppress the notice
Message: Return type of CI_Session_files_driver::close() should either be compatible with SessionHandlerInterface::close(): bool, or the #[\ReturnTypeWillChange] attribute should be used to temporarily suppress the notice
Message: Return type of CI_Session_files_driver::read($session_id) should either be compatible with SessionHandlerInterface::read(string $id): string|false, or the #[\ReturnTypeWillChange] attribute should be used to temporarily suppress the notice
Message: Return type of CI_Session_files_driver::write($session_id, $session_data) should either be compatible with SessionHandlerInterface::write(string $id, string $data): bool, or the #[\ReturnTypeWillChange] attribute should be used to temporarily suppress the notice
Message: Return type of CI_Session_files_driver::destroy($session_id) should either be compatible with SessionHandlerInterface::destroy(string $id): bool, or the #[\ReturnTypeWillChange] attribute should be used to temporarily suppress the notice
Message: Return type of CI_Session_files_driver::gc($maxlifetime) should either be compatible with SessionHandlerInterface::gc(int $max_lifetime): int|false, or the #[\ReturnTypeWillChange] attribute should be used to temporarily suppress the notice
Coagulation Analyser KCG-A100 is a high-performance semi-automated benchtop coagulation analyser. Incorporated automatic stirring system speeds up and aids in sample preparation. Reaction cuvette pre-heating saves time and reduces work-effort. Large storage memory and intuitive navigation allows quick review of previous result values.
Large storage memory and user-friendly review system
Output interface
Built-in thermal printer
Power supply
110V / 60Hz 220V / 50Hz
Stirring
Automated magnetic stirring motor for cuvette
Dimension
310 X 200 X 280 mm
Weight
4.5 Kgs
Features :
Single channel analysis
Pre-programmed test menu for single assays
Lower reagent consumption
Automated storage and printout
Preparation and incubation for samples/ reagents
Up to 7 point calibration or reference curves
Applications :
Used in small to medium sized pathological diagnostic laboratories, small or private hospital laboratories with wide range of applications in Hemostasis for diagnostic evaluation to test for Thrombo-embolytic disease, Thrombocytopenia, Impaired liver function or Hemophilia.
Meditronics