Message: Return type of CI_Session_files_driver::open($save_path, $name) should either be compatible with SessionHandlerInterface::open(string $path, string $name): bool, or the #[\ReturnTypeWillChange] attribute should be used to temporarily suppress the notice
Message: Return type of CI_Session_files_driver::close() should either be compatible with SessionHandlerInterface::close(): bool, or the #[\ReturnTypeWillChange] attribute should be used to temporarily suppress the notice
Message: Return type of CI_Session_files_driver::read($session_id) should either be compatible with SessionHandlerInterface::read(string $id): string|false, or the #[\ReturnTypeWillChange] attribute should be used to temporarily suppress the notice
Message: Return type of CI_Session_files_driver::write($session_id, $session_data) should either be compatible with SessionHandlerInterface::write(string $id, string $data): bool, or the #[\ReturnTypeWillChange] attribute should be used to temporarily suppress the notice
Message: Return type of CI_Session_files_driver::destroy($session_id) should either be compatible with SessionHandlerInterface::destroy(string $id): bool, or the #[\ReturnTypeWillChange] attribute should be used to temporarily suppress the notice
Message: Return type of CI_Session_files_driver::gc($maxlifetime) should either be compatible with SessionHandlerInterface::gc(int $max_lifetime): int|false, or the #[\ReturnTypeWillChange] attribute should be used to temporarily suppress the notice
Chemistry Analyser KCA-A201 is a high-performance fully automated benchtop clinical chemistry analyzer. Random access based automation system increases test productivity and accuracy. System incorporates cuvette washing station and contact-free reaction design for better hygiene practices.
Specifications :
Type
Fully Automated Random Access System
Throughput
Reagent 1 : 400 test/hr Reagent 2 : 600 test/hr With ISE : 400 test/hr
Analytical Methods
End-point, Multi-standard, Immuno-turbid metric, 1-2 reagent, Reagent/serum blank, etc.
Auto-alarm for crucial events (collision, reagent/ sample insufficiency, full waste container, etc.)
Calibration
Linear, Non-linear, Multi-point, K factor
Lamp
Halogen Lamp Wavelength : 340 nm – 810 nm
Absorbance Resolution
0.0001 Abs
Absorbance Accuracy
± 0.0003 Abs ; ( 0 Abs – 2.5 Abs)
Repeatability
≤ 2 %
Quality Control
Levy-Jennings quality control at 3 levels
Power Supply
220 V / 50 Hz or 110 V / 60 Hz
Dimension
1000 x 850 x 700 mm
Weight
137 Kgs
Features :
Random access automation system
Up to 80 assay modules
Intelligent multi-tasking operation
Standard/ Control/ STAT modes
Auto-alarms with Levy Jennings QC
Tele-diagnostic network interface
Bar code sample scanning (Optional)
Applications :
Used in small to medium sized pathological diagnostic laboratories with wide range of applications including determination of the concentration of enzymes, substrates, electrolytes, specific proteins, drugs of abuse, and therapeutic drugs in samples for diagnosis of toxicological effect on renal, cardiac, and liver function.
Meditronics
Meditronics International House 82 Queens Road Brighton BN1 3XE; UK