Message: Return type of CI_Session_files_driver::open($save_path, $name) should either be compatible with SessionHandlerInterface::open(string $path, string $name): bool, or the #[\ReturnTypeWillChange] attribute should be used to temporarily suppress the notice
Message: Return type of CI_Session_files_driver::close() should either be compatible with SessionHandlerInterface::close(): bool, or the #[\ReturnTypeWillChange] attribute should be used to temporarily suppress the notice
Message: Return type of CI_Session_files_driver::read($session_id) should either be compatible with SessionHandlerInterface::read(string $id): string|false, or the #[\ReturnTypeWillChange] attribute should be used to temporarily suppress the notice
Message: Return type of CI_Session_files_driver::write($session_id, $session_data) should either be compatible with SessionHandlerInterface::write(string $id, string $data): bool, or the #[\ReturnTypeWillChange] attribute should be used to temporarily suppress the notice
Message: Return type of CI_Session_files_driver::destroy($session_id) should either be compatible with SessionHandlerInterface::destroy(string $id): bool, or the #[\ReturnTypeWillChange] attribute should be used to temporarily suppress the notice
Message: Return type of CI_Session_files_driver::gc($maxlifetime) should either be compatible with SessionHandlerInterface::gc(int $max_lifetime): int|false, or the #[\ReturnTypeWillChange] attribute should be used to temporarily suppress the notice
Chemistry Analyser KCA-A200 is a high-performance fully automated benchtop clinical chemistry analyzer. Multi-standard and user programmable functionality enables customized usage. West guard Analysis and self-test feature improves productivity and accuracy.
Specifications :
Type
Fully Automated Analysis system
Throughput
140 tests per hour
Analytical Methods
End point, Kinetic, fixed time, Bi-chromatic, multi-standard, Two steps of end point and more
Assay Modules
Over 200 modules
Sample Slots
64 slots for standard and control
Sample Volume
1-100ul, 1ul / step
Reaction tray size
96 reaction cuvettes
Flow cell volume
32 ul
Reagent
Diluter : 1000ul, 1ul/step
Photometric Measuring range
0.0 – 3.0 OD (filters)
Probe Handling
With liquid sensor & automatic probe washing and crash function
Washing Reaction Cuvettes
Automatic Flow cell washing
Data Transmission
USB 2.0
Alarms
Reagent / sample alarm, Water alarm, Hit the needle alarm, Replace the reaction plate
Calibration
System Calibration :
Deduction of washer blank/ reagent blank Nonlinear linear or with 1-6 calibration standards
Lamp
7 high-quality 6 V/ 10 W Halogen lamp
Storage
Up to millions of analysis reports
Quality Control
Levy-Jennings chart and West guard analysis
Power Supply
220 V / 50 Hz or 110 V / 60 Hz
Dimension
600 x 500 x 410 mm
Features :
Intelligent Multi-tasking operation
Self-diagnosis and Auto-alarm
End point, Kinetic, fixed time, Bi-chromatic, multi-standard, two steps of end point
Standard/ Control/ STAT modes
Levy-Jennings chart and West guard Analysis QC
USB network interface
Applications :
Used in small to medium sized pathological diagnostic laboratories with wide range of applications including determination of the concentration of enzymes, substrates, electrolytes, specific proteins, drugs of abuse, and therapeutic drugs in samples for diagnosis of toxicological effect on renal, cardiac, and liver function.