Message: Return type of CI_Session_files_driver::open($save_path, $name) should either be compatible with SessionHandlerInterface::open(string $path, string $name): bool, or the #[\ReturnTypeWillChange] attribute should be used to temporarily suppress the notice
Message: Return type of CI_Session_files_driver::close() should either be compatible with SessionHandlerInterface::close(): bool, or the #[\ReturnTypeWillChange] attribute should be used to temporarily suppress the notice
Message: Return type of CI_Session_files_driver::read($session_id) should either be compatible with SessionHandlerInterface::read(string $id): string|false, or the #[\ReturnTypeWillChange] attribute should be used to temporarily suppress the notice
Message: Return type of CI_Session_files_driver::write($session_id, $session_data) should either be compatible with SessionHandlerInterface::write(string $id, string $data): bool, or the #[\ReturnTypeWillChange] attribute should be used to temporarily suppress the notice
Message: Return type of CI_Session_files_driver::destroy($session_id) should either be compatible with SessionHandlerInterface::destroy(string $id): bool, or the #[\ReturnTypeWillChange] attribute should be used to temporarily suppress the notice
Message: Return type of CI_Session_files_driver::gc($maxlifetime) should either be compatible with SessionHandlerInterface::gc(int $max_lifetime): int|false, or the #[\ReturnTypeWillChange] attribute should be used to temporarily suppress the notice
Anaesthesia System KAM-A102 is equipped with color LCD screen for clear display of trends, dosage rate and other setting parameters. Designed to suit adult as well as pediatric patients. System complies with closed, semi-closed, semi-open or assisted ventilation. Integrated system software allows real-time monitoring for loops, Paw, BPM, VT and lung compliance. Comprehensive audio-visual alarm indication for critical events increases patient safety.
Specifications :
Drive
Electronically controlled, pneumatic driven
Tidal Volume
20 ml – 1500 ml
Gas Configuration
O2, N2O
Flow Meter
Cascade, 0 L/min -10 L/min
LCD Display
7 inch LCD
Graphic Display
Waveforms of P-T, F-T
Vaporizer
Isoflurane / Enflurane / Sevoflurane / Halothane
I:E Range
4:1-1:8
Pressure Range
5 mbar - 80 mbar
P trigger Range
-20 cmH2O to 20 cmH2O
Respiration range
1 bpm - 99 bpm (1 bpm - 40 bpm under SIMV)
Calibration
Automatic
Pipeline Input
280 kPa - 600 kPa
Minute Volume
> 18 L/min
PEEP
Off 3 - 20 cm H2O
Run-time
> 30 minutes up to 2 hours
Hypoxic Safety System
N2O cut-off valve / O2 > 25%
Pressure Safety Valve
< 12.5 k Pa
Volume of CO2 absorber
1.5 L
Output Pressure
0.4 ± 0.1 mPa
Power Supply
AC 220V ± 10%, 50Hz ± 2%
Battery
Lead-acid battery 12V, 4Ah
Current
500 mA (Max)
Dimensions
700 x 850 x 1400 mm
Weight
65 Kgs
Features :
7 inch color LCD display
Pneumatic controlled flow
Ventilation modes: IPPV, SIMV, Manual, Stand-By
Vaporizer : Double (optional)
Auto-calibration
Suitable for adult as well as pediatric care
ACG outlet (optional)
AG Scavenging system (optional)
Yoke system (optional)
Selectetac (optional)
Applications :
Used in Surgical or Gynaecological departments to administer appropriate anaesthesia dosage at a specified rate to ensure effective sedation during surgeries and other invasive diagnostic or interventional procedures.
Meditronics
Meditronics International House 82 Queens Road Brighton BN1 3XE; UK