Message: Return type of CI_Session_files_driver::open($save_path, $name) should either be compatible with SessionHandlerInterface::open(string $path, string $name): bool, or the #[\ReturnTypeWillChange] attribute should be used to temporarily suppress the notice
Message: Return type of CI_Session_files_driver::close() should either be compatible with SessionHandlerInterface::close(): bool, or the #[\ReturnTypeWillChange] attribute should be used to temporarily suppress the notice
Message: Return type of CI_Session_files_driver::read($session_id) should either be compatible with SessionHandlerInterface::read(string $id): string|false, or the #[\ReturnTypeWillChange] attribute should be used to temporarily suppress the notice
Message: Return type of CI_Session_files_driver::write($session_id, $session_data) should either be compatible with SessionHandlerInterface::write(string $id, string $data): bool, or the #[\ReturnTypeWillChange] attribute should be used to temporarily suppress the notice
Message: Return type of CI_Session_files_driver::destroy($session_id) should either be compatible with SessionHandlerInterface::destroy(string $id): bool, or the #[\ReturnTypeWillChange] attribute should be used to temporarily suppress the notice
Message: Return type of CI_Session_files_driver::gc($maxlifetime) should either be compatible with SessionHandlerInterface::gc(int $max_lifetime): int|false, or the #[\ReturnTypeWillChange] attribute should be used to temporarily suppress the notice
Anaesthesia System KAM-A101 is equipped with color LCD screen for clear display of trends, dosage rate and other setting parameters. Designed to suit adult as well as pediatric patients. System complies with closed, semi-closed, semi-open or assisted ventilation. Integrated sensors and valves ensure risk prevention from system failure and increases patient safety.
Specifications :
Drive
Electronically controlled, bellow driven
Tidal Volume
0 ml – 1500 ml
Gas Configuration
O2, N2O
Flow Meter
1 l/min – 10 l/min
LCD Display
7 inch LCD
Vaporizer
Single [Isoflurane / Enflurane / Sevoflurane / Halothane]
Fresh Gas Compensation
25 l/min – 75 l/min
I:E Range
4:1-1:8
Monitoring
VT, MV, BPM, Paw
Modes of Ventilation
IPPV, SIMV, SIPPV, Manual
Respiration range
1 bpm – 100 bpm
Concentration Range
0% to 5%
Calibration
Automatic
Waveforms
Pressure-time, Flow-time, Pressure-volume loop
Hypoxic Safety System
N2O cut-off valve / O2 > 25%
Alarm
AC power failure, minute volume too high (low), airway pressure too high ( low ) and insufficiency of O2 and N2O
Used in Surgical or Gynaecological departments to administer appropriate anaesthesia dosage at a specified rate to ensure effective sedation during surgeries and other invasive diagnostic or interventional procedures.
Meditronics
Meditronics International House 82 Queens Road Brighton BN1 3XE; UK